Moving-Coil Meter Measures Low-Level Currents

Abstract: The MAX4172 IC substitutes a current amplifier for the shunt normally associated with a moving-coil meter. This circuit allows use of the moving-coil meter, even when the meter current is a large fraction of the current being measured.

The display of choice for certain applications remains the large moving-coil meter. While a moving-coil meter may lack the accuracy of a digital panel meter, the perceived extra information derived from the needle's rate of change cannot be matched by the digital alternative.

It is not always possible to attach a current shunt to analog meters, when the meter current is a large fraction of the current being measured. Although a disadvantage, it can be overcome by driving the meter from a separate supply voltage (Figure 1). The circuit shown for the MAX4172 drives a large 8-inch meter with full scale of 15mA.

Figure 1. This circuit allows use of a moving-coil meter in applications for which the meter current is a substantial fraction of the current being measured.
Figure 1. This circuit allows use of a moving-coil meter in applications for which the meter current is a substantial fraction of the current being measured.

IC1 was chosen from the many current-sense amplifiers available because it provides a separate supply-voltage terminal for the internal circuitry. (Other devices take power from the current being measured.) IC1's output current, IOUT, equals VSENSE/100Ω, where VSENSE is the voltage across RSENSE1. IOUT is boosted by the op amp and transistor, and the meter's full-scale current is easily changed by adjusting the value of RSENSE2.

This circuit also allows the meter display to be remote from the point of measurement. Note that the passive components are chosen for convenience rather than high accuracy, because moving-coil meters are not intended for applications that require precision measurement.

A similar version of this article appeared as a Design Idea in the March 3, 2005 issue of EDN magazine.


我们期待您的反馈!
喜欢?不喜欢?有待改善?或为我们提供建议?请与我们联系 — 我们将根据您的意见或建议改善我们的工作。 网页评价或提供建议


自动更新
需要自动接收最新发布的应用笔记吗?请订阅EE-Mail™ (English only)。



更多信息  APP 3536: Jun 20, 2005
MAX4172 低成本、精密的、高端电流检测放大器 完整的数据资料
(PDF, 96kB)
免费样品
MAX495 单/双/四路、微功耗、单电源、满摆幅运算放大器 完整的数据资料
(PDF, 248kB)
 

下载,PDF格式下载,PDF格式 (28kB)
 AN3536, AN 3536, APP3536, Appnote3536, Appnote 3536


      隐私权政策    法律声明

      © 2008 Maxim Integrated Products, Dallas Semiconductor版权所有